  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu
EVX100 Extractor
Manual for Installation, Use and Maintenance
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - EVX100 Extractor

Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HYT : 01949 862 012 F : 01949 862 003 E : se

Page 2 - Important

10Remove the old bulb from the holder.Fit the new bulb, taking care not to touch the glass of the bulb.Take care to ensure any tools used do not damag

Page 3

11InstallationPositioning the vent outlet:The motor unit can be turned to position the outlet to any of the four sides. 1. Open the decorative cover

Page 4

12InstallationInstalling the extractor:The extractor can be mounted directly into the ceiling, where space between the ceiling and joists permits, or

Page 5 - Using your Extractor

134. Drill the dierent holes required for the mounting, as below, using a drill bit suitable for the ceiling material :• The 150mm diameter vent o

Page 6

14ceiling, use a sleeve to prevent damage to the plasterboard when the four 10mm nuts and bolts are being tightened.When the ceiling is concrete, use

Page 7 - Care and Maintenance

15Installation into a false ceiling: (Two persons required)1. Open the decorative cover panel and remove the two grease filters.2. Remove the light p

Page 8

16fig. 153. The extractor is intended to be secured to the ceiling using the four adjustable spring-loaded clips; these are shown in the image below:4

Page 9

17the adjustment screw to secure the extractor firmly in positionNote:When fixing to an 18mm MDF false ceiling, four 2mm spacers have been provided to m

Page 10

18Ducting: The extractor can be used as a recirculation device or as a extraction device, depending on your installation.The hood is more eective whe

Page 11 - Installation

19Re-circulation:An internal air vent is required, as shown below. This ensures that the air is placed back in the kitchen after it has been filtered F

Page 12 - Fixing using the motor

2ImportantThe CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note tha

Page 13 - 90⁰, 180⁰

20Adjusting the position of the decorative cover panel: The decorative panel can be finalised by moving the positions of the cover hinges, as shown bel

Page 14

21Typical installation examples:

Page 15 - Installation into a false

22Changing the LightIMPORTANT: DO NOT PERFORM MAINTENANCE OR ATTEMPT TO CLEAN THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY.DO NOT

Page 16 - Frame - Reinforcement

23Synchronising the remote control with the extractorWhen the extractor is o, press and hold button B, and then switch the extractor on.After five sec

Page 17 - False ceiling (MDF)

24Mains Electricity ConnectionTHIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHE

Page 18 - Ducting:

25• The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured red.Note: Use a 3A FuseAssembly and electrical c

Page 19 - Extraction:

26Electrical InformationMains electrical voltage: 230 – 240Vac.Total rated power consumption EVX100: 382W.TroubleshootingPlease note:Your extractor is

Page 21

Please contact our Customer Care Department, or for Service on the details below.Customer Care Department • The Group Ltd. • Harby Road • Lang

Page 22 - Changing the Light

3IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC.At the end of its working life, the product must

Page 23

4Please note:• Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system.• Do

Page 24 - Mains Electricity Connection

5Using your ExtractorFor best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately

Page 25

6remote. Whilst the intensive function is active HI appears on the centre of the display and the bottom right hand dot flashes once a second.- To canc

Page 26 - Troubleshooting

7- To activate the clean air function, touch key E when the appliance is either on or o. When the clean air function is running, 24 will show on the

Page 27

8To reset the filter alarms, press button E for approximately 3 seconds when the extractor is switched o.To remove the grease filter follow the steps b

Page 28

9should remove and replace the charcoal filters.To attach a new charcoal filter, first open the cover panels and remove the grease filters as described ab