675-110306 1-1 Section 1 FURNACE EQUIPMENT 1.1 Furnace Description The LA-306 is a compact, near-infrared, conveyor belt furnace for laboratory and
Section 1 1-10 LA-306 Operation & Theory 1.4.5 STATUS Panel A. READY lamp When all zones have heated to their SV setpoint values and the con
Equipment Description 676-110306 1-11 1.4.6 GAS FLOW CONTROL Panel Atmosphere control is accomplished manually with flowmeters calibrated in lite
Section 1 1-12 LA-306 Operation & Theory 1.4.7 TEST Panel A. CALIBRATE pushbutton with lamp Whenever the LAMPS button is on, this button app
Section 1 1-2 LA-306 Operation & Theory 1.2 Furnace Views Figure 1-3 Furnace Front Elevation Figure 1-4 Entrance Elevation Figure 1-5
Equipment Description 676-110306 1-3 Figure 1-7 Rear Elevation Figure 1-8 Top Front View
Section 1 1-4 LA-306 Operation & Theory 1.3 Furnace Elements 1.3.1 Furnace Arrangement Parts are carried from the load station through the h
Equipment Description 676-110306 1-5 1.3.3 Entrance Baffle and Exhaust Stack The entrance baffle isolates the heating section from the ambient ai
Section 1 1-6 LA-306 Operation & Theory Zones. The heating chamber is partitioned into 3 separate zones using ceramic fiber dividers. The d
Equipment Description 676-110306 1-7 1.3.8 Cabinet Fans Cabinet Fan. The furnace is equipped with one (1) 10-inch diameter fan mounted on the und
Section 1 1-8 LA-306 Operation & Theory 1.4.2 POWER Panel A. MAIN POWER lamp When this WHITE light is ON, the furnace is connected to the p
Equipment Description 676-110306 1-9 1.4.4 TEMPERATURE Panel Figure 1-15 Zone Temperature Controllers The temperature control for each zone’s hea