Installing the Separator Below the Base of
the Cooktop
It is recommended that a 30mm clearance be left
between to base of the cooktop and the separator.
The separator shall be heat resistant, made of low
thermal conductivity material and shall be remova-
ble with the use of a tool for installation and ser-
vice.
30 mm
Space for
connections
Clearance
Separator
Fig.17
8 40
869
480
510
60
(2)
54
(1)
(1) 54mm from top of countertop
(2) at least 60mm between the back side of the cut-out and the back of the countertop.
Fig.16