CDA 7 Maintenance Manual
C-4 77 A7 48UU Rev03
De-palletizing the subsystem
1. Check the "TIP-N-TELL" indicator on one side of the main package.
2. Unpack the box, and cut the protection film to access the cabinet on its pallet.
3. Open the front and rear doors.
4. Release the cabinet by removing the shipping brackets, you will need to
remove six screws and six bolts, see the figure below.
3 Screws
Shipping brackets
3 bolts
Figure C-1. CDA 7 5330, Removing the Shipping Brackets
5. Close and lock the front and back doors.
6. Put the lowering ramp into position.
7. Lower the cabinet carefully (caution, weight exceeds 300 kg).
Precautions
Make sure that you have locked the doors before tilting the cabinet onto the
palletization rails. If you fail to do this, the front door (for example) could open
under its own weight and be seriously damaged when it touches the floor.
Check the shock indicator (shockwatch): when the front door is opened, check the
shock indicator (a small box) located inside the door at the top right. Steel balls
held in place by springs must be in the position on the drawing above. If they are
not, the cabinet has undoubtedly been subjected to a shock with sufficient
amplitude to make the balls fall, and you may need to make a more detailed
inspection.
Open the doors
Use the hexagonal spanner supplied in the tool box to open the doors.